October 2005
Delfield 980 S. Isabella Rd., Mt. Pleasant, MI 48858
(989) 773-7891 or (800) 733-8829 • Fax (989) 773-3210
www.delfield.com
Please read this
manual completely
before attempting to
install or operate
this equipment!
Notify carrier of
damage. Inspect all
components imme-
diately. See page 6.
INSTALLATION &
OPERATION
MANUAL
Specification Line
®
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - OPERATION

October 2005Delfield 980 S. Isabella Rd., Mt. Pleasant, MI 48858(989) 773-7891 or (800) 733-8829 • Fax (989) 773-3210www.delfield.comPlease read this

Page 2

10DelfieldSELF CONTAINED HINGED GLASS DOOR PASS-THRU REFRIGERATORMODEL VOLTAGE AMPS STORAGE SHELVES NO. OF UNIT BTU/HR BTU/HR SHIP NEMANUMBER CU. FT.

Page 3 - Table of Contents

11Specification LineSELF CONTAINED NARROW HINGED GLASS DOOR REACH-IN REFRIGERATORMODEL VOLTAGE AMPS STORAGE SHELVES NO. OF UNIT BTU/HR BTU/HR SHIP NEM

Page 4 - Table of Contents – Continued

12DelfieldSELF CONTAINED SOLID DOOR ROLL-IN REFRIGERATORMODEL VOLTAGE AMPS STORAGE SHELVES NO. OF UNIT BTU/HR BTU/HR SHIP NEMANUMBER CU. FT. SQ. FT. S

Page 5 - INTRODUCTION

13Specification LineSELF CONTAINED SOLID DOOR ROLL-IN FREEZERMODEL VOLTAGE AMPS STORAGE SHELVES NO. OF UNIT BTU/HR BTU/HR SHIP NEMANUMBER CU. FT. SQ.

Page 6 - SERIAL NUMBER

14DelfieldSOLID DOOR SINGLE SECTION DUAL TEMP REFRIGERATOR/FREEZERPASS-THRU UNITSMODEL VOLTAGE AMPS STORAGE NO. OF UNIT BTU/HR BTU/HR SHIP NEMANUMBER

Page 7 - SPECIFICATIONS

15Specification LineSOLID DOOR SINGLE SECTION DUAL TEMP REFRIGERATOR/FREEZER REACH-INSMODEL VOLTAGE AMPS STORAGE NO. OF UNIT BTU/HR BTU/HR SHIP NEMANU

Page 8

16DelfieldSELF CONTAINED SOLID DOOR CONVERT-A-TEMP REACH-INMODEL VOLTAGE AMPS STORAGE SHELVES NO. OF UNIT BTU/HR BTU/HR SHIP NEMANUMBER CU. FT. SQ. FT

Page 9

17Specification LineINSTALLATIONREACH-INS AND PASS-THRUSLocationCabinets represented in this manual are intended for indooruse only. Be sure the locat

Page 10 - Delfield

18DelfieldStabilizingIt is very important that all legs are properly adjusted tokeep the cabinet level, evenly distribute the weight and tomake sure t

Page 11 - Specification Line

19Specification LineLevelingAfter the cabinet has been placed in the desired location,cabinets with legs must be leveled. Level units from frontto bac

Page 12

2DelfieldIMPORTANT WARNING AND SAFETY INFORMATIONWARNINGRead this manual thoroughly before operating, installing, or performing maintenanceon the equi

Page 13

20DelfieldOperating ControlsREFRIGERATED WINE CABINETSRefrigerated wine cabinet units have a POWER ON/OFFswitch located on the front of the unit for c

Page 14

21Specification LineREFRIGERATED CABINETSRefrigerated cabinet units have a POWER ON/OFFswitch located on the front of the unit for controlling powerto

Page 15

22Delfield3. Adjust the time/temperature control for thefreezer to the desired temperature and timesettings.4. Set the temperature control for the des

Page 16

23Specification LineFailure to maintain a clean condenser coil can initially causehigh temperatures and excessive run times. Continuousoperation with

Page 17 - REACH-INS AND PASS-THRUS

24DelfieldProgrammingThree buttons are used for the programming: SET, UPand DOWN buttons. See Figure 7.NOTE: By lifting the gray plastic cover, but-to

Page 18 - ROLL-INS AND ROLL-THRU MODELS

25Specification LineTIMER CONTROLTwo and three sectionFreezer Defrost ControlAll two and three door freezers are equipped with aParagon Timer defrost

Page 19

26DelfieldOperationThe electric defrost controller is preset at the factory toprovide a defrost cycle every 6 hours (4 defrost per day).If it is neces

Page 20 - REFRIGERATED WINE CABINETS

27Specification LineLABOR OF 1-HOUR IS ALLOWED TO REPLACE:• Thermostat • Contactor/Relay• Door Jamb Switch • Transformer• Solenoid Coil • Evaporator/C

Page 21 - Freezer Compartment

28DelfieldSTANDARD TWO YEAR WARRANTY (Two year parts and labor, five year compressor)The Delfield Company (“Delfield”) warrants to the Original Purcha

Page 22 - Cleaning the Condenser Coil

29Specification LineADDITIONAL THREE YEAR PROTECTION PLAN (for motor-compressor only)In addition to the Standard One Year Warranty on theMotorCompress

Page 23 - Programming

3Specification LineSAFETY PRECAUTIONS... 2INTRODUCTION ...

Page 25 - Cycle Time

31Specification Line

Page 27

4DelfieldTable of Contents – Continued ROLL-INS AND ROLL-THRUS ... 18Location ...

Page 28

5Specification LineINTRODUCTIONGeneralModel numbers starting with the letters “SS” have astainless steel exterior and interior. Model numbersstarting

Page 29

6DelfieldRECEIVING AND INSPECTINGTHE EQUIPMENTCare should be taken during unloading so the equipmentis not damaged while being moved into the building

Page 30

7Specification LineSPECIFICATIONSHEATED ROLL-THRUMODEL VOLTAGE AMPS STORAGE SHELVES NO. OF UNIT BTU/HR BTU/HR SHIP NEMANUMBER CU. FT. SQ. FT. SHELVES

Page 31

8DelfieldSOLID DOOR NARROW HOT FOOD CABINET REACH-INMODEL VOLTAGE AMPS STORAGE SHELVES NO. OF UNIT BTU/HR BTU/HR SHIP NEMANUMBER CU. FT. SQ. FT. SHELV

Page 32 - DMSPECLINE 10/05

9Specification LineSELF CONTAINED SHALLOW SOLID DOOR REACH-IN REFRIGERATORMODEL VOLTAGE AMPS STORAGE SHELVES NO. OF UNIT BTU/HR BTU/HR SHIP NEMANUMBER